Product Series |
![]() |
![]() |
||||||
Lineator™ |
|
3-Phase Passive Harmonic Mitigation Filters for Variable Speed Drives. |
Will reduce harmonics to meet IEEE Std 519 limits where VFD's are used for Water / Waste Water, Oil & Gas, HVAC systems, etc. Exceeds 18-pulse performance in a smaller footprint, at lower cost and without sacrificing energy efficiency. | |||||
1-phase to Quasi 3-phase harmonic filter for 3-phase VFD's where only 1-phase power is available. Reduces ITHD to <12% while allowing for less derating of VFD. |
Used to lower current distortion and reduce the need for VFD derating in remote or residential locations where only 1-phase power is available and 3-phase motors are required. Applications include irrigation, waste water, Oil and Gas pumps, etc. | |||||||
![]() |
Ultra Low Loss Transformer that exceeds Nema STD TP1 guidelines for energy efficiency under linear loading and meets these guidelines under 'real world' non-linear loading. |
Ideal
for government, municipal, educational and institutional facilities where
LEED certification is required to meet 'High Performance' and Green' building
designations. |
||||||
NEMA TP1 Compliant Harmonic Mitigating Isolation Transformers. |
Designed to replace standard or K-rating transformers to enhance power quality and save energy when servicing 1-ph (120 V L-N) non-linear loads, such as personal computers and other power electronic equipment. | |||||||
NEMA TP1 Compliant Multiple output, phase shifting Harmonic Mitigating Isolation Transformer. |
Phase shifting and low zero sequence impedance transformers designed to cancel harmonics generated by switch-mode power supplies. Improves power quality by reducing voltage distortion and lowers energy costs in Data Centers, Telecom Sites, Broadcasting Studios and other facilities where high concentrations of sensitive power electronic equipment is in use. | |||||||
|
Appropriate for the raised floor environment. Primarily used for broadcasting, telecommunications, Internet service providers, data processing, call centers and all office environments with personal computers. | |||||||
Onics Harmonic Mitigating Remote Paneboard (HMRP). Up to 4 Circuit Breaker panelboards with built-in passive harmonic filtering. |
Eliminates the need for K-rated transformers and double ampacity neutrals. Ideal for broadcasting, telecommunications, data processing, call centers and all office environments with personal computers. Easily installed in either raised or solid floor applications. | |||||||
Neutral Current Eliminator. A high performance, zero sequence harmonic filter for removal of 3rd and other triplen harmonic currents from 3-phase, 4-wire distribution systems. |
Normally used in remedial applications to reduce neutral current. Applications include high tech facilities, such as broadcasting and telecommunications equipment rooms, computer labs in educational institutions, casinos, and any distribution system servicing a high density of non-linear loads such as personal computers. |
|||||||
|
Ideally suited for remedial applications to reduce neutral current and lower voltage harmonic distortion. Applications include high tech facilities, such as broadcasting and telecommunications equipment rooms, computer labs in educational institutions, casinos, and any distribution system servicing a high density of non-linear loads such as personal computers. |
|||||||
Series connected, 3-phase, 3-wire, phase shifting auto-transformer for control of 5th and 7th or 11th and 13th harmonics in 3-wire circuits with no neutral conductor. |
Allows for the creation of quasi 12, 18 or 24-Pulse systems where multiple 3-phase rectifiers, such as variable frequency drives, are in use. |
|||||||
Multiple output, phase shifting autotransformers for creation of quasi 12, 18 and 24-Pulse systems. |
Provides a low cost, highly effective solution for VFD harmonics by applying phase shifting strategies to multiple VFD applications. | |||||||
Drive isolation transformers with various phase shifting options. |
For use in multiple VFD applications to reduce harmonics by creating quasi 12, 18 and 24 pulse systems when full galvanic isolation is required. | |||||||
|